Figure 44 is the world’s first direct feed system for MOCVD materials developed by me. It was especially effective in precisely feeding TMI (Trimethyl indium), which is solid at room temperature. This system has been on the market since January 1989 and is still in operation at several semiconductor companies. This equipment can also be used to supply ALD raw materials.